Hitachi ZX890-7 Breaker Alarm Operating Procedures

This instruction show you guide on how to perform breaker alarm for Hitachi ZX890-7.

Preparation:
2023 Hitachi MPDr Diagnostic Software
Hitachi MPDR Dr.ZX Diagnositc Cable

Procedures:
1. Turn select/set switch (3) and select Breaker Alarm (4) on the Service Menu.

2. When pushing select/set switch (3), the Breaker Alarm screen appears.


3. Push select/set switch (3) and set the breaker alarm to ON.
3 

4. Turn select/set switch (3) and select Setting Time (5). Push select/set switch (3).

5. Turn select/set switch (3) and set the setting time until Breaker Alarm is activated. When pushing select/set switch (3),
the setting has been completed.
NOTE
When ON is selected on the setting screen of Breaker Alarm and the breaker is operated for the setting time
continuously, the buzzer sounds. (Refer to SYSTEM/Control System.)
6. When pushing back switch (1), the previous screen appears.

7. When pushing home switch (2), the basic screen appears.