Hitachi excavator Machine Setting and Monitor Setting are not displayed in initialization. When displaying Machine Setting and Monitor Setting, make enable by function settings of Hitachi MPDr..
Preparation:
2023 Hitachi MPDr Diagnostic Software
Hitachi MPDR Dr.ZX Diagnositc Cable
1. Turn select/set switch (3) and select Attachment Setting (4) on Service Menu.
2. When pushing select/set switch (3), the Attachment Setting screen appears.

3. Turn select/set switch (3) and select Attachment. When pushing select/set switch (3), the setting screen for selected Attachment appears.

4. Turn select/set switch (3) and select the item to be adjusted. When pushing select/set switch (3), the setting screen for
selected item appears.

NOTE
Type (5) is changed to braker as an example here. (Initial setting: Bucket)
5. When pushing select/set switch (3), the color of selected item data is changed. Turn select/set switch (3), change the data, and push select/set switch (3).

6. Turn select/set switch (3) and select a check mark. When pushing select/set switch (3), the setting has been
completed.

7. When pushing back switch (1), the previous screen appears.

8. When pushing home switch (2), the basic screen appears.